Common faults, cause analysis and solutions of industrial liquid filtration

2026-10-03 Visits:

During long-term operation of industrial fluid filtration systems, five typical faults including frequent clogging, flow attenuation, unqualified filtrate, liquid leakage and self-cleaning failure often cause production shutdown, consumable waste, defective products and environmental excess emissions. Based on field working conditions, we analyze fault causes and provide standardized solutions.


1. Frequent Clogging and Rapid Differential Pressure Rise


Causes: lack of front coarse filtration protection, large particles directly impacting fine filter layers; high liquid viscosity and high colloid/oil content; impurity concentration exceeding designed dirt holding capacity; excessively high selected filtration precision.

Solutions: build staged coarse and fine filtration system; adopt filter media with larger pore size and higher dirt holding capacity for high-viscosity fluid; add front sedimentation and oil removal procedures; reduce front-end precision reasonably to relieve back-end load.


2. Turbid Filtrate and Excessive Residual Impurities


Causes: cracked filter bags or cartridges; aging and loose sealing rings causing bypass leakage; insufficient filtration precision for fine particles; secondary pollution from internal scale deposition.

Solutions: replace damaged consumables regularly; renew aging seals and standardize installation; upgrade high-precision filter media; clean equipment cavity and pipelines periodically to remove sediment.


3. Continuous Flow Reduction and Insufficient Flux


Causes: clogged filter media; blocked pipelines and insufficient valve opening; low system pressure; increased liquid viscosity and poor fluidity under low temperature.

Solutions: clean or replace filter media timely; dredge pipelines and fully open valves; adjust system working pressure; adopt low-temperature resistant filter materials and optimize pipeline heat preservation for low-temperature conditions.


4. Equipment Sealing Leakage


Causes: aging and deformed flange/end cover seals; uneven installation and loose pressure covers; overpressure operation; seal failure caused by acid-base corrosion.

Solutions: replace corrosion-resistant seals regularly; standardize uniform fastening installation; control working pressure within rated range; adopt PTFE and fluororubber seals for corrosive media.


5. Invalid Self-Cleaning and Persistent Clogging


Causes: worn scrapers/brushes with poor fitting; excessively high differential pressure trigger parameters; blocked drain pipelines; sticky impurities adhering to screens.
Solutions: replace worn scrapers and brushes to ensure tight fitting; lower differential pressure threshold properly; dredge drain pipes and increase blowdown frequency; match pre-dilution and pre-treatment for high-viscosity working conditions.
Standard daily inspection, differential pressure monitoring and regular maintenance are core methods to reduce filtration faults, extend service life of equipment and consumables, and cut factory operating costs.